$12,849.10
Add to Cart
Ultrasound Color Doppler Portable Color Doppler Ultrasound System Touch screen
Only 1 available
Details
Shipping: Australia: free (more destinations)
Condition: Used
*The store has not been updated recently. You may want to contact the merchant to confirm the availability of the product.
Download the catalog Feature:-22 inch color LED Touch Screen-With multiple probes to fit different uses and budgets-Imaging Mode: B, BB, M, CD, PWD, CWD, DirPwr, Pwr-High Definition Multiple Color Doppler mode imaging, include supports most Doppler imaging and advanced imaging processing for cardiac, vascular access, and OB diagnostics.-Can be equipped in addition with 3D and panoramic image processing for volume reconstruction, visualization, segmentation, and measurement.-Can install and run all applications with Microsoft? Windows? including patient management systems for better follow up, as well as network tools to access PACS data-Large volume store and preview, edit records (image, voice comments, cineloop video) by hardisk, USB flash disk, DVD-Triplex Display: Real-time triplex display B/ Color Doppler/ Pulsed Spectral Doppler (Three TGCs can be adjusted respectively)-THI (Tissue Harmonic Imaging) technology: Suppress speckle noise, brighten image and improve the image quality-One-key Optimization: One key for eight-parameter adjustment, easy image optimization.-Powerful Measurement Software: Versatile clinic-oriented measuring software package -Image Management: Versatile image format/ large capacity cineloop storage/ preview/ edit-Can maintain and update by internet-Space saving by the integration of color doppler ultrasound scanner and office computer, and can either lay on a desk or be wall mounted.-Can be controlled either through a regular PC keyboard and a mouse, or a dedicated ultrasound keyboard. -Except general use, special suit for use in operation room or ambulances-2 probe socketsImaging Modes· B· B+B· 4B· B+M· M· B-steer· Compound + Trapezoid· Color Doppler (CFM)· Power Doppler (PDI)· Directional Power Doppler (DPDI)· Pulsed Wave Doppler (PWD)· B+PWD (Duplex)· B+CFM/PDI/DPDI+PWD (Triplex)· High Pulse Repetition Frequency (HPRF)· Tissue Harmonic Imaging (THI)Ultrasound imaging· ultrasound image size: automatically adjustable to screen resolution· gray scale: 256· color scale: 256· full motion and full size real-time ultrasound imaging, up to 120 fps (depends on selected scan depth, scan angle, focus mode, High Line Density setting, computer speed)· cineloop recording/play: several thousands frames (depends on computer memory size and scan mode)· zoom mode: from 60% to 600% in all modes (Scan, Freeze, B, B+B, 4B, Doppler modes, M-zoom, cineloop and etc)· viewing area variable for frame rate maximizing: 6 steps· thumbnail mode: up to 32 images· "Freeze" mode· "Auto Freeze" modeScanning Method· electronic linear· electronic convex· electronic microconvex· scanning depth: 2-30 cmTransducers· convex, micro-convex, linear, transvaginalo from 2,0 MHz to 12,0 MHzo multifrequency· automatic transducer recognitionColor Doppler· PRF variable: 0.5-10 kHz· wall filter settings: 3 steps (5%, %10%, 15% PRF)· gain control: 50 dB· angle steering for linear transducers: ±10°· real-time spatial filter: 4 values· CFM palette: 10 maps· PDI palette: 11 maps· B/Color priority control· color threshold control· CFM baseline control· Doppler frequency selection: 2 frequencies / each transducer· color frame averaging: 8 values· Transparent Color Mapping (TCM): 10 valuesAutomatic Image Optimization· single click auto adjustment:o B-image: gain, dynamic range, TGC sliderso Color Doppler: CFM/PDI/DPDI gaino Pulsed Waved Doppler: baseline, invert, PRFPulsed Wave Doppler· PRF variable: 1-15 kHz· wall filter settings: 16 steps (2.5%-20% PRF)· gain control: 50 dB· angle steering for linear transducers: ±10°· real-time trace line with automatic calculation of spectrum parameters· stereo sound: volume control· PWD palette: 12 maps· Doppler frequency selection: 2 frequencies / each transducerFocusingdigital transmit focusing multi focus mode: transmit/receive focusing programmable focus area presetsdynamic focus mode: transmit variable focus dynamic receive focusProcessingHigh Line Density scan mode for better resolution TGC Control, 5-10 sliders (customizable) 40 dB dynamic range: 120 dB, 8 values overall gain control M - mode sweep speed control acoustic power control variable frame averaging brightness, contrast advanced gamma control: 8 fixed curves, 8 user defined (custom) scan direction, rotation, up-down controls negative / positive control bi-linear interpolation echo enhancement control noise rejection function speckle reduction and structure improvement PureView: 8 algorithmsFunctionsmouse / trackball / keyboard operation anatomical icons with transducer position indicator direct e-mail sending with image or video attachment via Internet DICOM file push to server printing on system printer unlimited programmable presets for clinically specific imaging TV output via computer display adapterFile Formatsimage and video save / load AVI JPG BMP PNG TIF DCM (DICOM uncompressed) DCM (DICOM-JPEG RGB/YBR) DCM (DICOM-JPEG RGB/YBR Video) TPD (Picture Data) TVD (Video Data)DICOMVerification SCU Modality Worklist (MWL) SCU Modality Performed Procedure Step (MPPS) SCU Store SCU (images, cines) Print SCU (grayscale, color) Interface Customizationthe set of predefined skin schemes for software interface the set of predefined buttons images Multilanguage support, languages: Chinese English German Italian Korean Lithuanian Magyar Polish Romanian Russian SpanishB+M, B+PW layout position, size ultrasound area size font sizeGeneral Measurements and CalculationsB and Color Doppler mode general measurements and calculations Distance Length (method: 1 trace) Area, Circumference (methods: 1 ellipse, 1 trace, 1 distance) Volume (methods: 1 distance, 2 distances, 3 distances, 1 ellipse) Angle (methods: 2 distances, 3 distances) Stenosis % (methods: 2 distances, 2 ellipse or trace areas) A/B Ratio (methods: 2 distances, 2 ellipse or trace areas, 2 ellipse or trace circumferences)M mode general measurements and calculations Distance, Time, Velocity Heart Rate (methods: 1 beat, 2 beats) Stenosis % (method: 2 distances) A/B Ratio (methods: 2 distances, 2 times, 2 velocities)PW mode general measurements and calculations One-point PW measurements and calculations: Velocity Pressure Gradient (PG)Two-points PW measurements and calculations: Velocities difference Pressure Gradients (PG) difference Time interval Acceleration Resistivity Index (RI) Heart Rate (methods: 1 beat, 2 beats) Velocity minimum and maximum Pressure Gradient (PG) minimum and maximumTrace-based PW measurements and calculations: Trace Time Trace Velocity min, max, mean Trace Pressure Gradient (PG) min, max, mean Velocity Time Integral (VTI) Pulsatility Index (PI)A/B Ratios of one-point PW measurements: Velocities A/B Ratio Pressure Gradients (PG) A/B RatioA/B Ratios of two-point PW measurements: Velocity differences A/B Ratio Pressure Gradient (PG) differences A/B Ratio Time differences A/B Ratio Accelerations A/B Ratio Resistivity Indexes A/B RatioA/B Ratios of trace-based PW measurements: Velocity means A/B Ratio Pressure Gradient (PG) means A/B Ratio Pulsatility Indexes A/B Ratio Velocity Time Integrals A/B RatioPW mode Human Cardiology measurements and calculationsLeft Ventricle: LVOT Diam, LVOT VTI, LVOT Vmax, SV (Stroke Volume), SI (Stroke Volume Index), CO (Cardiac Output), CI (Cardiac Index), dP:dt (Delta Pressure : Delta Time), MPI (Left Ventricle Myocardial Performance Index) Mitral Valve: MVA(PHT) (Mitral Valve Area using Pressure Half Time), MVA using Continuity Equation (LVOT Diam, MV VTI; LVOT Diam, MV Vmax), dP:dt, E/A ratio Aortic Valve: AVA (Aortic Valve Area) using Continuity Equation (LVOT Diam, AV VTI; LVOT Diam, AV Vmax), AVI (Aortic Valve Index), DPI (Dimensionless Performance Index), AV PHT (Aortic Valve Pressure Half Time) Right Ventricle: RVOT Diam, RVOT VTI, RVOT Vmax, dP:dt, RV MPI (Right Ventricle Myocardial Performance Index), MPAP (Mean Pulmonary Artery Pressure) Tricuspid Valve: TVA (Tricuspid Valve Area) using Continuity Equation (RVOT Diam, TV VTI; RVOT Diam, TV Vmax); TV E/A ratio, TV PHT Pulmonic Valve: PVA (Pulmonic Valve Area) using Continuity Equation (RVOT Diam, PV VTI; RVOT Diam, PV Vmax), PVI (Pulmonic Valve Index), DPI (Dimensionless Performance Index), PV PHT (Pulmonic Valve Pressure Half Time) Pulmonary Vein; Hepatic Vein Shunts: Qp:Qs (Pulmonary-Systemic Flow Ratio)Human Measurements and Calculations PackagesHuman General calculations package Measurements: the same as general measurements of different modes (B, M, PW) Calculations: BSA via Height and Weight, BSA via Weight, Hip Angles (α, β), Femoral Head Coverage (FHC) PW mode calculations: HR, SV using Flow Area, SV using Flow Diameter, SI, CO, CI, Area calculation using Continuity Equation (methods: Area and VTI, Area and Velocity, Diameter and VTI, Diameter and Velocity, Velocity Ratio (S/D, D/S), dP:dt, Flow Volume (methods: Diameter, Area), PHT, MVAHuman Obstetrics / Gynecology (OB / GYN) calculations package Measurements: LMP (entered or from calendar), AC, BPD, FL, HC, FTA, AAPD, ATD, TAPD, TTD, CRL, GS, HL, TL, UL, OFD, BOD, Cereb, Clav, Rad, AFI, FHR Estimated date of birth (EDD) calculations: EDD(LMP), EDD(GA), EDD(AUA) Ratios: FL / AC, FL / HC, FL / BPD, HC / AC, CI Estimated Fetal Weight (EFW) calculations: EFW(AC), EFW(AC,BPD), EFW(AC,FL), EFW(AC,HC), EFW(AC,HC,BPD), EFW(FL), EFW(AC,FL,HC), EFW(AC,BPD,FL), EFW(AC,BPD,FL,HC), EFW(BPD,FL,FTA), EFW(BPD,ATD), EFW(BPD,TTD), EFW(BPD,TAPD,TTD), EFW(BPD,FL,TAPD,TTD) Selected EFW values are used for calculation of Average EFW Gestational Age (GA) calculations: GA(AC), GA(BPD), GA(CRL), GA(FL), GA(GS), GA(HC), GA(HL), GA(OFD), GA(TL), GA(UL), GA(HC/AC), GA(FTA),GA(ATD), GA(TAPD), GA(TTD), GA(BOD), GA(Cereb), GA(Clav) Fetal Growth estimation (trending): AC(GA), BPD(GA), CRL(GA), FL(GA), GS(GA), HC(GA), HL(GA), OFD(GA), TL(GA), UL(GA), [FL/AC](GA), [FL/HC](GA), [HC/AC](GA), EFW(GA), AAPD(GA), ATD(GA), TAPD(GA), TTD(GA), BOD(GA), Cereb(GA), Rad(GA), Clav(GA), AFI(GA), FHR(GA) S














CN, guangdong